Fatigue-Qualified Dispensable Silicone Gel Seals for High-Frequency Moving Parts

Technology
In development
University

Development and fatigue qualification of a dispensable silicone gel seal for high-frequency moving parts. Food/medical-grade platinum-cure silicone gels are cured in place across 1–3 mm gaps, with modulus selected to avoid pump-out and fatigue crack growth. Validated through adhesion testing, 160 Hz ±1 mm fatigue tests past 7 million cycles, and dispensing process development.

Overview

This project develops a fatigue-qualified, dispensable silicone gel seal for high-frequency moving parts. The seal is formed by dispensing commercially available, food/medical-grade platinum-cure silicone gels into an assembled device, where they cure in place to create a compliant, tacky, self-sealing barrier across 1–3 mm gaps. Rather than defaulting to the softest gel, the material modulus is selected from mechanics to avoid wave resonance and inertial pump-out under high-frequency motion while keeping the cyclic energy release rate below the elastomer fatigue threshold.

The result is a validated material, primer, and dispensing recipe that can be integrated into devices requiring leak-tightness, damping, and durability over millions of cycles. The approach leverages mature commercial materials and existing regulatory pathways, concentrating the development effort on adhesion and fatigue qualification.

Technical specifications

Key elements of the development program:

  • Screen 4–6 food/medical-grade addition-cure silicone gels and soft liquid silicone rubbers for modulus and damping using rheology and DMA, extended to 160 Hz by time–temperature superposition.
  • Measure swelling and property retention after exposure to personal care products.
  • Quantify fracture energy of gel–housing plastic interfaces with and without primers.
  • Develop a dispensing recipe covering needle selection, flow rate, and curing schedule; confirm fill and leak-tightness using optical coherence tomography and dye penetration.
  • Run fatigue tests at ±1 mm displacement and 160 Hz past 7 million cycles, before and after product exposure, using laser-speckle imaging to track strain fields and debond onset.
  • Deliver a ranked material list, dispensing SOP, and fatigue/leak data.

Target device parameters include 1–3 mm gaps, ±1 mm cyclic motion, and high-frequency operation. Design targets are based on a tearing-energy threshold to enable indefinite seal life when modulus and adhesion are correctly matched.

Technology readiness level

The base silicone gels are commercially available at TRL 9: addition-cure silicones are sold in bulk, dispensed with meter-mix equipment, and available in food-contact and medical grades. The remaining risk is not chemistry but durability — datasheet hardness does not predict whether a soft gel will survive millions of high-frequency cycles or remain bonded to the housing. This project is designed to close that gap through validated mechanics, adhesion data, and fatigue qualification, delivering a TRL 5–6 seal solution ready for integration into production.


About Case Western Reserve University

Case Western Reserve University is a comprehensive private research university anchored in Cleveland’s University Circle with a high‑intensity research enterprise. Its campus is co‑located with major hospital systems, giving industry partners access to clinical collaborators, regulatory know‑how, and real‑world validation environments. A large open‑access makerspace, shared core facilities, and an engineering co‑op program connect companies to rapid prototyping, testing, and talent pipelines. Research is supported by competitive federal funding from agencies such as NIH, NSF, DOE, and DoD. A dedicated technology transfer office, working with corporate engagement and entrepreneurship programs, supports IP strategy, licensing, sponsored research, and startup formation.

Halo home
Partner smarter. Move faster.
Get new partnering requests
delivered to your inbox.