PhytoCentric Solutions LLC

Real-time biosensor for rapid microbial contamination detection

Technology
In development
Company

A reagent-free biosensor system detects bacteria and fungi at 0.1 CFU within 0.03 seconds. Optical interferometry and spectrometer-based analysis generate results that are transmitted to a mobile app and returned within 10 seconds. Validated against multiple organisms, with reported performance spanning 10 CFU/ml to 10^5 CFU/ml in 0.03 seconds. Designed for food safety, water quality monitoring, and home-use microbial detection with projected cost under $1 per test.

Overview

A biosensor system detects microorganisms—including bacteria and fungi—at extremely low concentrations (0.1 CFU) within 0.03 seconds. The technology is paired with a mobile phone application that transmits biosensor readings to a central processing system, which converts the data into positive or negative results and returns them to the user within 10 seconds. This rapid, reagent-free platform targets needs in food safety, water quality monitoring, clinical diagnostics, and home-use microbial detection, where speed, sensitivity, and low cost are essential. The total projected cost per test is less than $1.00, supporting economically feasible large-scale or repeated testing.

Technical specifications

Core technology:

  • A modified component of Type II alveolar epithelial cells placed on a silicon disk serves as the biosensing element
  • Optical interferometry captures biofilm movement in response to test agents, plotted as light intensity versus wavelength
  • Tungsten white light passes through a spectrometer and computer program to detect microbial contamination
  • No reagents are required for operation

Validated performance:

  • Successfully detected E. coli O157:H7, Listeria, Salmonella, Fusarium, and Aspergillus
  • Detects E. coli K12, E. coli O157:H7, Listeria, and Salmonella at concentrations from 10 CFU/ml to 10^5 CFU/ml in 0.03 seconds
  • Tested in laboratory deionized water and Colorado river irrigation water
  • Over 100 compounds evaluated, including detection at ppb-range concentrations

System integration:

  • Mobile phone app transfers biosensor data to a central computer system
  • Results delivered back to the phone app within 10 seconds
  • Portable, inexpensive prototype design suitable for field and home settings
Technology readiness level

The current biosensor model is rated at Technical Readiness Level 6 (TRL 6) under the Department of Defense TRL system, indicating late-stage prototype development validated in a simulated operational environment. Preliminary data from collaborative testing between PhytoCentric Solutions LLC and the biosensor developer have demonstrated reliable detection across multiple pathogen types and water matrices. A proposed next-phase validation would assess performance under real home-setting conditions, targeting detection of bacteria and fungi of interest at 0.1 CFU within 0.03 seconds, with culture-method enumeration for result confirmation. This next-phase validation is expected to take 6–12 months and would also involve development of the mobile telephone application and supporting computer engineering infrastructure.

Halo home
Partner smarter. Move faster.
Get new partnering requests
delivered to your inbox.